Home /
PRECOG / Industries

Protecting critical infrastructure in every industry

PRECOG predicts the failure of any complex machine driven by an electric motor, to prevent downtime and unplanned maintenance and to ensure business continuity. It can build on existing measurement infrastructure and provides its own sensors where needed.

Strategic value

What operators and stakeholders gain

Risk mitigation

PRECOG reduces the risk of sudden, costly breakdowns by finding problems before they escalate.

Operational efficiency

Predictive insight supports data-driven decisions, reduces emergency repair costs and improves the lifetime of the assets.

Brand protection

Reliable infrastructure helps to uphold the standards that customers and guests expect.

Sustainability and ESG

Early fault detection leads to more efficient energy use and less waste, which supports sustainability targets and reduces the environmental impact.

Hotels and buildings

PRECOG for hotels, offices, hospitals and shopping centres

PRECOG ensures continuous building operation by predicting failures about two weeks in advance for the whole complex infrastructure, whether it consists of critical or non-critical motors.

Critical motors
  • Elevators and escalators
  • Water pumps
  • Heating and ventilation systems
  • Air conditioning systems
  • Fire pumps
  • Sewage and drainage pumps
  • Backup generators

Critical motors are essential for safety, infrastructure and uninterrupted operation.

Non-critical motors
  • Kitchen appliances
  • Laundry equipment
  • Automatic doors
  • Pool and spa pumps
  • Smart blinds and curtains
  • Cleaning robots and vacuums

Non-critical motors are still important, but their failure does not threaten the overall operation of the building.

The quality of a hotel is often judged by its design, service and comfort, yet much of its function runs silently behind the scenes, powered by critical and non-critical motors. They operate everything from air conditioning to elevators and from kitchen equipment to wastewater systems. Counting the critical and non-critical motors is the starting point for working out how many measuring devices a building needs.

Critical building infrastructure

Pumps, air conditioning, refrigeration and lifts

PRECOG ensures continuous operation by predicting failures about two weeks in advance for high-power water and air pumps, AC units, refrigeration units, elevators and escalators, and any other equipment driven by an electric motor.

Elevators and escalators
  • Drive motors and traction units
  • Gearboxes, brakes and counterweight systems
  • Control electronics and safety modules
  • Door operators, sensors and communication systems
  • Ventilation and cooling components

PRECOG analyses power, current, temperature, vibration, position and other physical factors.

Pumping systems
  • Water and wastewater pumps
  • Booster sets and circulation pumps
  • Motors, impellers and bearings
  • Variable frequency drives and control electronics
  • Cooling fans, seals and coupling units

PRECOG analyses power, current, temperature, vibration, pressure, flow and other physical factors.

Building and facility systems
  • Air compressors and cooling pumps
  • HVAC units
  • Conveyor and lifting equipment
  • Power distribution and control panels

One monitoring approach for the whole technical infrastructure of a building.

PRECOG ensures maximum uptime, energy efficiency and passenger safety across lifts, pumping systems and building infrastructure.

Railways and public transport

Turnouts, doors, barriers and vehicles

periodic motion analysis show how it works in practice.
Rail vehicle system What PRECOG monitors
Brake systems Wear of brake pads and discs, overheating and abnormal vibration
Compressed air supply units Leakage rates and air pressure stability, compressor vibration and efficiency, moisture or filter contamination
Doors and coupling systems Wear of actuators and motors, early detection of electrical and positioning failures

Manufacturing

Robots, conveyors, presses, machining and utilities

PRECOG ensures continuous operation by predicting failures about two weeks in advance for welding robots, paint line infrastructure, conveyor belts, press machines and any other equipment driven by an electric motor. The tables show typical equipment, the measured factors and the faults that can be detected.

Assembly, paint and material handling

Equipment Measured Detected
Robotic arms (welding, assembly, handling) Power, vibration, current Motor fatigue, joint misalignment, gearbox wear
Conveyor belts and transfer units Power, vibration Belt wear, roller misalignment, drive motor degradation
Torque tools Torque, current Calibration drift, mechanical stress
Press and stamping machines Vibration, pressure, temperature Misalignment, abnormal force, lubrication failure
CNC and machining centres Vibration, temperature, power Spindle or bearing wear, tool imbalance
Paint line infrastructure (booths, mixers, ovens) Power, temperature Fan fatigue, heater degradation, uneven heating
Spray nozzles and filtration units Pressure, flow, power Clogging, reduced spray quality, filter blockage
Forklifts and lift systems Power, temperature Overheating, hydraulic issues
Conveyors and elevators (internal transport) Power, vibration Drive or belt fatigue, tension anomalies

Machining, welding, repair and positioning equipment

Equipment Measured Detected
CNC lathes, main spindle units Vibration Bearing wear, component wear, imbalance, prediction of manufacturing anomalies and prevention of machining inaccuracies
Machining and repair stations for critical components Vibration, power, current, temperature Spindle or bearing wear, tool imbalance, drive degradation
Welding cells, rotating and positioning equipment Current, power, vibration, position Motor fatigue, shaft or gearbox wear, positioning error
Composite and honeycomb repair cells Temperature, power, vibration, position Heat profile deviation, motion anomaly, fan or drive wear
Motorised measurement and inspection stations Position, vibration, current, temperature Actuator failure, calibration drift, loss of repeatability

Material handling, hydraulics and safety equipment

Equipment Measured Detected
Roller conveyors Power, vibration, temperature Bearing fatigue, motor overheating, brake wear, misalignment
Positioning actuators Power, position, vibration, torque Gear wear, encoder drift, shock load fatigue
Hydraulic units Pressure, vibration, power, temperature Seal leakage, pump wear, cavitation, actuator failure
Cooling fans Power, vibration, temperature Fan bearing wear, overheating, dust accumulation
Buffer units and stopper actuators Power, vibration, position Cushion wear, spring fatigue, malfunction, jamming
Access gates Power, vibration Motor and gear wear
Emergency stops Power, temperature Contact fatigue, control unit degradation
Optical and load sensors Power, temperature, position Electronics degradation, calibration drift, structural strain

Utilities and plant infrastructure

Equipment Measured Detected
Air compressors, vacuum pumps Power, temperature, pressure, vibration Overheating, leakage, bearing or seal wear
HVAC systems and cooling towers Power, vibration, temperature, airflow Fan imbalance, filter clogging, pump wear, motor fatigue
Ventilation and exhaust fans Power, temperature Degradation, imbalance

Food and drink production

Raw material handling with belt, roller and chain conveyors, bucket elevators and palletisers. Mixing and processing with agitators, dosing and metering pumps, homogenisers and pasteurisers with circulation pumps. Filling and packaging lines with filling, capping, labelling, wrapping and case-packing machines. Automated storage and retrieval systems, product lifts and access gates. Utilities such as water pumps for supply, cleaning in place and cooling, compressors, refrigeration units, cooling towers and fire suppression pumps. Motor-driven sampling systems for quality control.

Data centres and telecoms

Cooling, power and IT indicators

Mechanical systems

  • Server room cooling fans and CRAC systems, with speed fluctuation and signs of lost cooling
  • Cooling motors of UPS and inverter modules, with bearing fatigue and overheating trends
  • Cooling motors of communication and monitoring stations, with fan fatigue and rising vibration

IT and network indicators

  • Network, operations and failure KPIs predicted before an outage
  • Hardware reliability, for example through physical clock signals on circuit boards

See the telecommunication case study.

Airports and logistics

Passenger, baggage, security and airside equipment

Area Equipment
Passenger transportation Elevators, escalators and moving walkways
Baggage handling Conveyor belts, automated sorting systems with motor-driven diverters, lifts and arms
Security and operations Sliding doors, revolving doors, access gates, fire and smoke extraction fans and pumps
Airside and ground infrastructure Hangar and taxiway gates, passenger boarding bridges, motorised runway and taxiway lighting
Power and climate control HVAC fans, compressors and pumps, diesel generator starter motors and fuel pumps

The same approach applies to logistics centres: conveyor motors and belts, automated lifts and hoists that suffer overload fatigue, and the cooling and HVAC equipment of the building.

Energy, water and process industries

Pumps, compressors, fans and process equipment

Oil, gas and process plants

Area Equipment and detected faults
Raw material handling and transport Crude oil pumps (seal wear), pipeline compressors (bearing wear), loading pumps (motor fatigue)
Refining process equipment Distillation pumps (shaft misalignment), heat exchangers (fouling), furnace blowers (fan fatigue), catalyst dosing pumps (cavitation)
Utilities and plant infrastructure Cooling towers (pump wear), steam boilers (feed pump failure), air compressors (overheating, leaks), refrigeration units (compressor wear)
Material movement and storage Tank valves (wear), conveyors and elevators (belt fatigue), access gates (motor failure)
Quality control and safety Sampling units (actuator failure), ventilation fans (motor degradation), firewater pumps (seal wear)
Upstream systems Hot oil pumps, cooling water circulation pumps, soft water and layer water pumps, firewater pumps and gasoil pumps. Measured: vibration, load, pressure-holding cycles and start frequency. Detected: bearing wear, shaft misalignment, seal leakage, overheating and fire-risk patterns

Electricity grid substations

Equipment Detected
Transformer oil cooling fans and pumps Bearing wear, temperature anomaly, reduced output
GIS compressors, valve actuators of SF6 and air systems Signs of seal and pressure loss, rising friction, position deviation
Motor drives of breakers and switches Rising torque, mechanical play
Ventilation and air conditioning motors Load swings, overheating
Motorised gates and door drives Gear wear, starting current peaks
Firewater pumps, smoke extraction and pressurisation fans Seal wear, motor current anomaly